Description: FEATURE Charging 3-stage: constant current(MPPT), constant voltage(Absorption Voltage), floating charge Selectable battery type Vented / Sealed / Gel / NiCd / Lithium battery (default is Sealed) (defined voltage for other battery by user) Soft start time ≤1S, Dynamic response and recovery time 100us Max efficiency ≥98.1%, PV utilization ≥99% In order to reduce the cost of electricity caused by high current, PV and battery each have two terminals MULTIPLE ELECTRONIC PROTECTIONS Short-circuting Reverse-current Overcharging Overload Over-discharging Reverse polarity protection Maximum PV Input Power Ensure that the solar input voltage exceeds 3v or is higher than the battery voltage. 12 Volt Battery Systems: Maximum PV input power 720 watts, recommended solar input voltage range 20 - 80 volts DC. 24 Volt Battery Systems: Maximum PV input power 1440 watts, recommended PV input voltage range 37 - 105 VDC 36 volt battery system: 2100 watt maximum PV input, recommended PV input voltage range 50 - 150 volts DC 48 volt battery system: 2800 watt maximum PV input, recommended PV input voltage range 72 - 150 volts DC Installation Procedure Installation Procedure Install the switch between the controller and the battery. Install a switch between the controller and the PV module. Check that the "+" and "-" of the PV module and the "+" and "-" of the battery are correctly connected. Turn on the battery switch first, then turn on the PV switch. LCD display ESC: Exit the setting without saving the data. UP: Scroll down, adjust the parameter by increasing the value. DOWN: Scroll up, adjust the parameter by decreasing the value. ENTER: Short press to move to the next setting page, long press to exit the setting and save the data. Display Code Meaning Display Code Meaning EQU: Load voltage compensation BST: Pulse charging voltage FLD: Load voltage hold LDV: Over-discharge voltage LRV: Over-discharge recovery voltage BST - r: Pulse charge recovery voltage Battery type: FLD/SEL/Gel/Lithium/Use Warning and Caution 1. the battery voltage must be higher than 12v for the controller to start. 2. make sure that the solar input voltage exceeds 3v or the battery voltage. 3. hold the wiring correctly and do not change the wiring. 3. hold the wiring correctly and do not change the wiring. pay attention to the order of the terminal wiring. 4. if it is a lead acid battery, if it is not professional, do not set any parameter, because in addition to the lithium battery, the controller also works well in the standard state. 5. do not connect solar inverters / generators / wind turbines to the controller. 6. Install the controller indoors to prevent the components from entering the water. 7.Maximum PV input voltage (voc): 180 V dc, the controller cannot work for a long time under this voltage, which will damage the controller. 8. Disconnect the battery and reconnect to save the configuration. 40A 30A 20A MPPT solar charge controller(Fan cooling) 12V/24V(auto detection);32V(setting) MPPT efficiency>99%,Peak conversion efficiency >98% DSP processors technology ensure high speed and performance Multi-stage charging mode Protection: PV array short circuit , PV reverse polarity , Battery reverse polarity , Over charging , Output short circuit Equalization charging function BTS function Models ICharer MPPT 2420 2430 2440 Rated charge current 20A/30A/40A System Voltage 12/24V Auto recognized Max PV Input Power 260W(12V) 260W(12V)/ 260W(12V) 260W(12V)/520W(12V) 1040W (24V) Solar panel inputrange 16.8V-60V(12V) 33.6V-60V(24V) /16.8V-60V(12V) 33.6V-60V(24V)/16.8V-60V(12V)33.6V-60V(24V) BatteryVoltageAutom aticRecognition 12VSystem(DC8.7V-DC15.SV)24VSystem(DC16V-DC31V) 36VSystem(DC33V-DC41V)48VSystem(DC42V-DC64V) Maximum batteryvoltage 8V-32V Battery type Battery type LVD Maintenance-free lead-acid battery, GEL, lead-acid Flooded battery :10.8V LVR Maintenance-free lead-acid battery, GEL, lead-acid Flooded battery :12.6V HVD Lead acid battery 16V Temperature compensationcoefficient -4mV/°C/2V(25°C) Fan-onTemperature >45℃ Fan-offTemperature <40℃ Size(mm) 247.3*201*80.3 NeWteight(Kg) 1.5 Light control voltage ≤90%, No condensation Enclosure IP30 Opertation Temperature -20°C~+55°C Storage Temperature -30°C~+70°C
Price: 13.99 USD
Location: Chino, California
End Time: 2024-02-19T07:24:44.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Current Output: 60A/40A/30A/20A
Pliability: Flexible
System Configuration: Hybrid
Power Source: Solar
Maximum Input Voltage: 12V/24V/36V/48V
Inverter Technology: Hybrid
Brand: EASUN
Current Type: DC
Type: Solar Charge Controller
Voltage: 12V/2V/36V/48V
Features: Indicator Light, LCD Display, Portable
Charging Mode: MPPT (Maximum Power Point Tracking)
Protection Properties: Discharge Protection, Overcharge Protection, Overcurrent Protection, Overload Protection
Available Variations
Color: 60A 12V/24V/36V/48V
Price: 79.99 USD
Available Quantity: 0
Quantity Sold: 0
Color: 40A 12V/24V
Price: 59.99 USD
Available Quantity: 10
Quantity Sold: 0
Color: 30A 12V/24V
Price: 49.99 USD
Available Quantity: 10
Quantity Sold: 0
Color: 20A 12V/24V
Price: 39.99 USD
Available Quantity: 10
Quantity Sold: 0
Color: 2 Pair Cable Adapter
Price: 13.99 USD
Available Quantity: 20
Quantity Sold: 0