Description: This product is sold worldwide, if you are using it in the United States, please contact me before purchasing! E3 electrocardiograph Introduction E3 is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc. Note: The device sold to the countries and regions that have FDA certification requirement does not support automatic analysis and diagnosis function. Function 1)High resolution thermal-array output system(8 dots/mm), no adjustment required. Frequency Response is up to 150Hz. 2)Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal. 3)Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing. 4)Support for auto 1×12, auto 1×12+1, auto 2×6, auto 2×6+1, auto 3×4, auto 3×4+1, auto 4×3, auto 3-2+1, auto 3-2, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, paper speed, sensitivity, calibration signal, name of lead, filter state and patient’s information. Information including printed waveform length, output measurement parameter, diagnostic conclusion, superposition QRS waveform, histogram, trend chart and interval list, can be set, and with time print function, which meets different requirements. 5)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden. 6)Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm. 7)The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered. 8)1000 cases can be stored by the built-in memory, convenient for case review and statistic. 9)Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report. 10)Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit. 11)External USB keyboard, code scanner, printer and USB storage device can be connected. Performance Input way: Floating and defibrillation protection Lead: Standard 12 leads Patient leakage current: <10µA Input impedance: ≥100MΩ(1Hz) Frequency response: 0.01Hz~300 Hz(-3dB) Time constant: ≥3.2s CMRR: >123dB Filter: AC Filter(AC50/60 Hz), EMG Filter (25 Hz/35 Hz (-3 dB)), DFT Filter, Low-pass Filter Recording way: Thermal printing system Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper Time base selection(paper speed): 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5% within 0.2s~2.0s Gain control(sensitivity):2.5, 5,10, 20, 40, 10/5, 20/10mm/mV, accuracy is ±5%; Standard sensitivity: 10 mm/mV±0.2 mm/mV Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze. Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze. Manual record: record according to manual record format. Measurement parameters: HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5) amplitude, S(V1) amplitude, R(V5)+S(V1) amplitude Product safety type: Class I type CF defibrillation-proof applied part Polarization resistance voltage: ±950 mV Noise level: ≤12 µVp-p ECG signal input sampling frequency: 32 kHz Waveform data processing sampling frequency: 1 kHz Sampling precision: 24-bit The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected Pacing detection channel: all leads Accuracy of input signal: ±5%. Amplitude quantization: ≤5µV/LSB Interchannel time deviation: <100 µs Power supply: AC: 100V~240V(50/60Hz) DC: 7.4V/5000mAh rechargeable lithium battery Degree of protection against ingress of liquid: IPX0 Working mode: continuous working Accessories Standard configuration: 1)A lead cable 2)A limb electrode 3)A chest electrode 4)A thermal recording paper 5)A power cord 6)An earth wire 7)A user manual Physical characteristic Working environment Temperature: 5℃~40℃ Relative humidity: 25%~95%(non-condensing) Atmospheric pressure: 700 hPa~1060 hPa Transport and storage environment Temperature: -20 ℃~+55 ℃ Relative humidity: ≤95% Atmospheric pressure: 500 hPa~1060 hPa Dimension: 315mm(L)×200mm(W)×77mm(H) Weight: 1.6Kg About Us Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you. Shipping 1.Our shipping rates include the cost of shipping, handling, packaging,custom fees are not included,buyers pay the taxes. 2.We usually shipped out the items the next business day after payment has been verified (Sat. & Sun. excluded.) Contact Us Please contact us first if you are not satisfied with the item when you receive it or haven't received item after 30 days, We will try our best to solve any problem. Open case and negative feedback is not conducive to solve the problem for both sides. hope you can understand! All emails will be answered within 24 hours on weekdays(but within 48hours on weekends).Please don't hesitate to contact us with any queries or comments about our items or your problem. Only English operating instruction,if you need any other language,please contact us!
Price: 519 USD
Location: Elk Grove Village, Illinois
End Time: 2024-10-04T09:18:39.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
MPN: Does not apply
Number of Channels: 3
ECG & EKG Machine Type: Electrocardiograph
Intended Use/Discipline: Biological Laboratory, Dental Laboratory, Emergency Medicine
Operation: Digital
Features: Printer
Model: E3
Country/Region of Manufacture: China